Kinetic-ID

Fixed and mobile cGMP HMI · ISO Class 7–8 · Grade C–D

Cleanroom HMI Workstation for ISO Class 7–8

Two form factors, one platform. ID-View is the fixed wall-mounted monitor. ID-Flow is the mobile cart. Both are validated for ISO Class 7–8 and EU GMP Grade C to D. Both are 304L stainless, ingress protection rated, and browser-based for MES, LIMS and EBR at the point of work.

Kinetic-ID cleanroom HMI workstation (ID-Flow 5 dual-screen) in pharmaceutical environment

Trusted by the world's leading regulated manufacturers

Johnson & JohnsonPfizerEli LillyBiogenSanofiNovartis

The range

Cleanroom HMI solutions, fixed and mobile

Kinetic-ID supplies cleanroom HMI in two form factors: a wall-mounted monitor and a mobile cart. Both are validated as a Grade C–D HMI for ISO Class 7–8 EU GMP environments. Both use 304L stainless, ingress protection rated, with the same integration stack. The decision is mostly about operator workflow, not capability.

Cleanroom computer equipment, fixed and mobile

ID-View and ID-Flow are both cleanroom computer equipment validated for the same ISO classes and cleaned with the same protocols. The decision is mostly about where the operator sits: fixed station goes to ID-View, moving between process steps goes to ID-Flow. Same compliance pack applies to either.

Kinetic-ID ID-View wall-mounted cleanroom HMI monitor

Fixed HMI

ID-View, wall-mounted cleanroom monitor

A sealed stainless steel monitor, ingress protection rated, available in several screen sizes with either a wall bracket or a pivot arm. Pick this when the operator station is permanent, such as a fill line, an inspection bench or a packaging hall.

  • Wall-fixing or pivot-arm
  • MES, EBR, DCS access

ID-View specifications

Monitor sizes 21.5" · 24" · 27"
Enclosure rating Ingress protection rated
Stainless steel 304L
Surface roughness (Ra) ≤ 0.8 µm
Cleanroom classification ISO 7–8 · EU GMP C–D
Mount VESA 100 · wall or pivot-arm
Wireless Wi-Fi 6 (802.11ax)
ID-View product page
Kinetic-ID ID-Flow 5 mobile cleanroom HMI workstation

Mobile HMI

ID-Flow, mobile cleanroom workstation

A mobile HMI cart with hot-swap batteries and a single or dual 24" screen setup. Pick this when the operator moves to the process, including batch production, sampling rounds and troubleshooting that doesn't fit one fixed location.

  • Hot-swap batteries, 24/7 runtime
  • MES, LIMS, EBR, DCS access

ID-Flow specifications · cleanroom computer workstation

Dimensions (H × W × D) 1180 × 640 × 560 mm
Chassis weight Dependent on configuration
Stainless steel 304L
IP rating Ingress protection rated
Cleanroom classification ISO 7–8 · EU GMP C–D
Battery Li-ion 500 Wh, hot-swap
Runtime per charge 8–12 hours
Screens Single or dual 24"
Wireless Wi-Fi 6 (802.11ax)
ID-Flow 5 product page

Standard chassis dimensions and configuration shown for both ID-View and ID-Flow. Every unit is built to specification — dimensions, materials, battery, screens and peripherals are configured per deployment. Confirmed values issued at quotation.

Fully customizable

Cleanroom grade, stainless finish, battery, screens, peripherals and integrations, all configured to your specification. Full IQ/OQ/PQ documentation packages available on request.

Customize to your spec

Why Kinetic-ID

Why pharmaceutical and life sciences teams choose Kinetic-ID

Designed for regulated environments

Not retrofitted from medical or office hardware. Engineered specifically for cGMP, GMP, and ISO Class environments.

Hot-swap battery architecture

Lithium battery system — two 500 Wh packs designed for continuous shift operation. Battery exchange in approximately 5 minutes, planned around natural workflow breaks.

Validated for MES, LIMS, SCADA, DCS

Active deployments across Emerson DeltaV, Werum PAS-X, LabVantage, Siemens Opcenter, Rockwell FactoryTalk, and more.

UK manufactured, full traceability

Material certificates, welding procedure specifications, and validation documentation issued with every unit.

Pilot units available to evaluate on site

Get an ID-Flow unit into your cleanroom for evaluation before committing to a deployment.

Long-lifecycle commercial platform

NHS fleets in continuous service since 2019. 5-year Kinetic-Power warranty. Designed for decade-plus operational lifespans.

The problem

Three ways fixed terminals cost you batches

Data lives at fixed terminals. Work happens on the floor.

Every walk to a fixed MES terminal risks a transcription error and delays the batch. Operators lose 20–40 minutes per shift to the commute.

Manual re-entry invites audit findings.

Paper-to-system transcription is the most-cited deviation source in FDA 483 letters. Each manual step is a CAPA risk.

Upstream deviations go undetected until batch failure.

Without floor-level visibility, QC and engineering see deviations only after the batch record is compiled, hours or days after they could have been corrected.

Hygienic design

Ingress-free surface design

ID-View and ID-Flow share the same hygienic design principle: a smooth, welded stainless steel envelope with no exposed fasteners or inset seams. Particulates and solvent residue have nowhere to settle that an operator can't wipe. Every external surface is cleanable in one pass.

Welded stainless, no crevices

The envelope is continuous-welded 304L stainless with surface roughness Ra ≤ 0.8 µm. Corners are rounded and the top slopes, so particulates have nowhere to settle.

Cleans with what you already use

Your existing cleaning protocols will work: IPA, hydrogen peroxide, peracetic acid, quats. If you need material traceability documentation for validation, we issue it on request.

Built against Annex 1

Designed against the EU GMP Annex 1 requirements for fixed equipment in controlled and aseptic environments. If you want support building this into your contamination control strategy for PQ, we can help.

Case study

Proven across life science environments

Active deployment across US life sciences sites integrating with Emerson DeltaV and Syncade.

Life Sciences

· ID-Flow 3, 5, 6 and 9

Stellix Global Services & NECI

4

ID-Flow variants deployed across US life sciences sites

316L

fully sealed watertight stainless developed for this customer

DeltaV

+ Syncade · Emerson MES and DCS integration

With Kinetic-ID, you get exactly what you want, and they will focus it to your needs on a practical level.

Stellix Global Services & NECI, Emerson Impact Partner

ROI calculator

Estimate your own savings

Presets:

Facility & shifts

0510

QA & investment

01260
0%35%80%

* Directional estimates based on operations expertise. Use your internal numbers for precision. Weeks/month: 4.33. Working days/week: 5. Maintenance defaulted to €250/cart/year from year 3. 3-year analysis period.

Integrations

Compatible with the systems already on your floor

Browser-based access to MES, LIMS, eBR, DCS and corporate IT. The same chassis serves as an MES HMI, a LIMS terminal, or a DCS console depending on the shift. No new network segments, no cloud dependencies.

MES

  • Emerson Syncade
  • Körber PAS-X
  • Werum PAS-X MES
  • Siemens Opcenter
  • Rockwell FactoryTalk
  • Tulip

LIMS

  • LabVantage
  • STARLIMS
  • LabWare
  • Thermo SampleManager

DCS

  • Emerson DeltaV

eBR

  • Werum PAS-X MES
  • MasterControl Manufacturing

Corporate IT

  • SAP ERP
  • Active Directory / SSO
  • OPC-UA, HL7 connectivity

Compliance

Built to be defended in audit

Every ID-Flow 5 ships with the documentation your validation and QA teams need to clear change control and internal review.

Certifications

  • ISO 9001:2015 · IQN-2021-0834
  • ISO 13485:2016 · MD-2022-1146

Standards referenced

ISO 14644-1 EU GMP Annex 1 FDA 21 CFR Part 11 EU Annex 11 EU MDR 2017/745

Validation support: IQ/OQ/PQ documentation packages issued with every deployment. Change control and revision tracking supported per ICH Q9 risk management. Low particle-shed design suited to ISO Class 7–8 / EU GMP Grade C–D environments.

Deployment process

How a deployment works

  1. Discovery call

    30 minutes. One site, one line, one application. We’ll recommend the right configuration.

  2. Workflow review

    Site survey, configuration spec, validation requirements signed off with your team.

  3. Pilot deployment (optional)

    A single unit on site for typical 30-day evaluation. Full validation support throughout.

  4. Roll-out & support

    Standard 6–8 week build, IQ/OQ/PQ documentation, 5-year Kinetic-Power warranty, ongoing support.

For your team

One cart. Four teams benefit.

For Operations

Faster deviation response. No operator hours lost walking to fixed terminals. Battery system designed for continuous shift operation; two 500 Wh packs, planned battery exchange around natural workflow breaks.

For Quality

Reduced transcription risk. Change control is audit-ready. IQ/OQ/PQ documentation ships with every unit.

For Engineering

Supports your existing MES, LIMS, eBR and corporate IT. No new network segments to approve.

For IT / OT

TPM-backed endpoints. Validated Wi-Fi 6 stack. AD/SSO integration. No third-party cloud dependency.

Pilot programme

Pilot a unit in your facility

Get an ID-Flow unit on site to evaluate against your operational and validation requirements. Typical pilots run around 30 days, though we’ll work with your team on the right timeline. Site survey, setup support and IQ/OQ documentation included.

Site survey

Pre-deployment review of cleanroom grade, network, peripheral requirements.

Setup & training

On-site configuration, operator walkthrough, validation support.

IQ/OQ documentation

Full validation pack issued for change control review.

FAQ

Frequently asked questions

How do I choose between fixed (ID-View) and mobile (ID-Flow)?

Choose ID-View (fixed) when the operator has a dedicated station, such as aseptic processing lines, fill-finish operations, or permanent inspection points. Choose ID-Flow (mobile) when operators move between multiple process steps or need point-of-work access during batch rounds, sampling or troubleshooting. Many facilities deploy both. The consultation includes a site-layout review to confirm the right mix.

Which cleanroom grades is it validated for?

ID-Flow 5 is suitable for ISO Class 7 and Class 8 environments per ISO 14644-1, equivalent to EU GMP Grade C and Grade D. The 304L stainless chassis, ingress protection rated enclosure and low particle-shed construction support cleanroom validation. Site-specific validation is supported by IQ/OQ/PQ documentation packages issued with every deployment.

Which LIMS platforms are validated?

Active deployments of the mobile HMI (ID-Flow) exist with LabVantage, STARLIMS, LabWare and Thermo SampleManager. Integration is browser-based over Wi-Fi 6. For the fixed HMI (ID-View), LIMS has not been formally validated as a pre-configured package; it is compatible via the same browser-based access but customer validation applies. Kinetic-ID does not host or process LIMS data. Audit trails stay inside your existing systems, compatible with 21 CFR Part 11 and EU Annex 11.

How does the battery hot-swap work?

The cart uses two 500 Wh Li-ion battery packs. Battery exchange takes approximately 5 minutes and requires removing access screws from the underside of the cart. Plan exchanges for shift changes or natural workflow breaks rather than mid-task — the brief operational pause is best treated as a scheduled handover rather than an interruption.

What's the lead time for a standard configuration?

Standard configurations ship in 6–8 weeks from order confirmation. Custom configurations (specific peripheral bundles, branded fascia, non-standard screen sizes) add 2–4 weeks. Every unit ships with IQ/OQ documentation and a validated delivery file.

Can we pilot a single unit before scaling?

Yes. Get an ID-Flow unit on site to evaluate against your operational and validation requirements. Typical pilots run around 30 days, though we’ll work with your team on the right timeline. Site survey, setup support and IQ/OQ documentation are included.

Is the cart suitable for Grade A or B aseptic processing zones?

ID-Flow 5 is specified for Grade C and Grade D environments. For Grade A or B aseptic processing zones, look at ID-Flow 9 — fully sealed 316L stainless built specifically for critical zones. We can recommend the right product based on your room classification.

Book a 30-minute consultation

One site, one line, one pain point. We'll tell you whether the ID-Flow 5 fits, and give you the validation documentation you'd need to defend the decision.

Life Sciences Brochure preview

Life Sciences Brochure

The full ID-Flow range, cleanroom grades, IP ratings, battery architectures, and IQ/OQ/PQ validation support.

Book a 30-minute consultation

We'll respond within one business day. Your details are not shared.

Get the Life Sciences Brochure

Tell us where to send it. Required for our records.

By submitting you agree to be contacted about your enquiry. We don't share your details.

Before you go — get the brochure

Full ID-Flow range, cleanroom grades, IP ratings, battery architectures, and IQ/OQ/PQ validation support.

By submitting you agree to be contacted about your enquiry. We don’t share your details.